Research Update: Two-phase Flow Research - Key Findings and Impact
April 13, 2017
HTRI recently concluded research in the following topics: Vertical Upflow – pressure drop and void fraction Vertical Upflow – flow regime map Vertical Downflow – pressure drop and void fraction Vertical Downflow – flow regime The details of the research, results, and discussions have been published in HTRI research reports TPF-14,...
Read More
-
F-24 Demonstration of RFU as Research Tool
March 27, 2017
In 2013 HTRI commissioned the Rotating Fouling Unit (RFU). With its smaller volume, shorter run duration, and faster turnaround, the RFU serves as a screening device for the High Temperature Fouling Units (HTFU-1 and HTFU-2) and is ideal for fouling impact studies on specific variables. Initial fouling tests and fouling impact...
Read More
-
Beyond the Basics: Understanding the Xist Vibration Report
January 16, 2017
Avoiding flow-induced vibration problems in shell-and-tube exchangers is an important task best accomplished at the design stage. Xist® completes a screening analysis using mechanistic-based methods that have been validated with real cases and data. Because there are two types of vibration (tube and acoustic) and several excitation mechanisms, careful examination of...